一、抗干擾 異變頻介質損耗測試儀產品概述

是發(fa)電(dian)(dian)廠、變(bian)電(dian)(dian)站等現場或實(shi)驗室測(ce)試(shi)(shi)(shi)各種高壓(ya)(ya)電(dian)(dian)力設備介(jie)損(sun)(sun)(sun)正(zheng)切值及電(dian)(dian)容量的高精度(du)測(ce)試(shi)(shi)(shi)儀器(qi)。儀器(qi)介(jie)質(zhi)損(sun)(sun)(sun)耗(hao)測(ce)試(shi)(shi)(shi)儀為一體化結構,內(nei)置介(jie)損(sun)(sun)(sun)測(ce)試(shi)(shi)(shi)電(dian)(dian)橋(qiao),可(ke)變(bian)頻調壓(ya)(ya)電(dian)(dian)源(yuan),升壓(ya)(ya)變(bian)壓(ya)(ya)器(qi)和SF6高穩定度(du)標準(zhun)電(dian)(dian)容器(qi)。測(ce)試(shi)(shi)(shi)高壓(ya)(ya)源(yuan)由儀器(qi)內(nei)部的逆變(bian)器(qi)產(chan)生,經變(bian)壓(ya)(ya)器(qi)升壓(ya)(ya)后用于被試(shi)(shi)(shi)品測(ce)試(shi)(shi)(shi)。頻率可(ke)變(bian)為50Hz、47.5Hz52.5Hz、45Hz55Hz、60Hz、57.5Hz62.5Hz、55Hz65Hz,采用數字(zi)陷波技術,避開(kai)了工頻電(dian)(dian)場對測(ce)試(shi)(shi)(shi)的干(gan)擾(rao),從根本上(shang)解(jie)決(jue)了強電(dian)(dian)場干(gan)擾(rao)下(xia)準(zhun)確(que)測(ce)量的難(nan)題。同(tong)時適(shi)用于全部停電(dian)(dian)后用發(fa)電(dian)(dian)機供(gong)電(dian)(dian)檢測(ce)的場合(he)。該儀器(qi)配以絕緣(yuan)油(you)杯加(jia)溫控裝(zhuang)置可(ke)測(ce)試(shi)(shi)(shi)絕緣(yuan)油(you)介(jie)質(zhi)損(sun)(sun)(sun)耗(hao)。

儀器主要具有如下特點:

l 科(ke)學*的數據管理

儀器數據(ju)可以(yi)通過(guo)U盤導(dao)出,可在(zai)任意一臺PC機上通過(guo)我(wo)公司軟件,查看和管理數據(ju)

l 異頻介質損耗測試儀多種測試模式

儀器使用(yong)內高壓(ya)、內標準的方(fang)式測試,正接(jie)法(fa)、反(fan)接(jie)法(fa)、自激法(fa).

l CVT測試一(yi)步到位

該儀器(qi)還可以測(ce)試全密封(feng)的CVT(電(dian)(dian)容(rong)式(shi)電(dian)(dian)壓互感(gan)器(qi))C1、C2的介(jie)損和(he)電(dian)(dian)容(rong)量。


l 不拆高(gao)壓引線(xian)測量CVT

儀器(qi)可在(zai)不拆(chai)除(chu)CVT高壓(ya)引(yin)線的(de)情況下正確(que)測量CVT的(de)介質損(sun)耗值(zhi)和電容值(zhi)。

l CVT反接屏蔽法測量C0

儀器可采用反接屏蔽(bi)法測量CVT上端C0的介質損耗值和電容(rong)值。

l 高速采樣信號

儀器內部(bu)的逆變(bian)器和采(cai)樣(yang)電(dian)路全部(bu)由數(shu)字化控制,輸出(chu)電(dian)壓連續可調。

l 多重(zhong)保護安全可(ke)靠

儀器(qi)具備(bei)輸入電(dian)壓波動、高壓電(dian)流、輸出短路、電(dian)源故障、過壓、過流、溫度等多(duo)重保(bao)護措施,保(bao)證(zheng)了儀器(qi)安全、可(ke)靠。儀器(qi)還具備(bei)設(she)置接(jie)地檢(jian)測功(gong)能,確保(bao)不接(jie)地設(she)備(bei)不允許升壓。

二、工作原理

在(zai)(zai)交流電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)作(zuo)用下,電(dian)(dian)(dian)(dian)(dian)介(jie)(jie)(jie)質(zhi)(zhi)要消(xiao)耗(hao)部(bu)分電(dian)(dian)(dian)(dian)(dian)能(neng),這部(bu)分電(dian)(dian)(dian)(dian)(dian)能(neng)將轉變為(wei)熱能(neng)產生損耗(hao)。這種能(neng)量(liang)(liang)(liang)(liang)(liang)損耗(hao)叫做電(dian)(dian)(dian)(dian)(dian)介(jie)(jie)(jie)質(zhi)(zhi)的(de)損耗(hao)。當電(dian)(dian)(dian)(dian)(dian)介(jie)(jie)(jie)質(zhi)(zhi)上施加交流電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)時(shi),電(dian)(dian)(dian)(dian)(dian)介(jie)(jie)(jie)質(zhi)(zhi)中(zhong)的(de)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)和(he)(he)電(dian)(dian)(dian)(dian)(dian)流間成(cheng)在(zai)(zai)相角(jiao)(jiao)(jiao)(jiao)差(cha)ψ,ψ的(de)余角(jiao)(jiao)(jiao)(jiao)δ稱為(wei)介(jie)(jie)(jie)質(zhi)(zhi)損耗(hao)角(jiao)(jiao)(jiao)(jiao),δ的(de)正(zheng)(zheng)切(qie)tgδ稱為(wei)介(jie)(jie)(jie)質(zhi)(zhi)損耗(hao)角(jiao)(jiao)(jiao)(jiao)正(zheng)(zheng)切(qie)。tgδ值是用來衡量(liang)(liang)(liang)(liang)(liang)電(dian)(dian)(dian)(dian)(dian)介(jie)(jie)(jie)質(zhi)(zhi)損耗(hao)的(de)參數。儀器(qi)測(ce)(ce)(ce)量(liang)(liang)(liang)(liang)(liang)線路(lu)(lu)(lu)包(bao)括一標準回路(lu)(lu)(lu)(Cn)和(he)(he)一被試(shi)(shi)(shi)(shi)回路(lu)(lu)(lu)(Cx),如(ru)圖2—1所示(shi)。標準回路(lu)(lu)(lu)由(you)內置高穩定度標準電(dian)(dian)(dian)(dian)(dian)容器(qi)與測(ce)(ce)(ce)量(liang)(liang)(liang)(liang)(liang)線路(lu)(lu)(lu)組(zu)成(cheng),被試(shi)(shi)(shi)(shi)回路(lu)(lu)(lu)由(you)被試(shi)(shi)(shi)(shi)品和(he)(he)測(ce)(ce)(ce)量(liang)(liang)(liang)(liang)(liang)線路(lu)(lu)(lu)組(zu)成(cheng)。測(ce)(ce)(ce)量(liang)(liang)(liang)(liang)(liang)線路(lu)(lu)(lu)由(you)取樣(yang)電(dian)(dian)(dian)(dian)(dian)阻與前置放大器(qi)和(he)(he)A/D轉換器(qi)組(zu)成(cheng)。通(tong)過測(ce)(ce)(ce)量(liang)(liang)(liang)(liang)(liang)電(dian)(dian)(dian)(dian)(dian)路(lu)(lu)(lu)分別測(ce)(ce)(ce)得標準回路(lu)(lu)(lu)電(dian)(dian)(dian)(dian)(dian)流與被試(shi)(shi)(shi)(shi)回路(lu)(lu)(lu)電(dian)(dian)(dian)(dian)(dian)流幅(fu)值及其相位(wei)差(cha),再由(you)數字(zi)(zi)信號處(chu)理器(qi)運用數字(zi)(zi)化實時(shi)采集方法(fa),通(tong)過矢量(liang)(liang)(liang)(liang)(liang)運算得出試(shi)(shi)(shi)(shi)品的(de)電(dian)(dian)(dian)(dian)(dian)容值和(he)(he)介(jie)(jie)(jie)質(zhi)(zhi)損耗(hao)正(zheng)(zheng)切(qie)值。

安全措施:

1、 使用本儀器前(qian)一定要認真閱讀本手(shou)冊。

2、操作者應具備一(yi)般(ban)電氣設備或儀器(qi)的使用常識。

3、儀器應避免(mian)劇(ju)烈振動。

4、儀器必須(xu)可(ke)靠接地(di),防止(zhi)觸電(dian)危險。

5、測試結束后,按(an)復位鍵,關(guan)掉電(dian)源開關(guan),嚴禁帶電(dian)拆裝各測試電(dian)纜和(he)更換油樣。

使用條(tiao)件 -15℃~40℃;RH<80%

電 源 AC 220V±10%,頻率無限制
交流高壓輸出 400V~2200V ±2% ,每隔100V 50VA
直流高壓輸出 200V~600V ±2%,每隔50V
溫控感應爐 zui大功率500W
溫度控制范圍<100℃
溫度控制誤差 ±0.5℃
溫度測量分辨率 0.1℃
控溫時間 室溫到(dao)90℃, 小于20min

三、抗干擾 異(yi)變頻介質損(sun)耗測試儀注意事項
1、遵守本單位的(de)高壓試驗安全工作(zuo)規程。
2、高壓試驗(yan)必(bi)須由2名以上工(gong)作人員參加(jia),1人操作,1人監護。
3、接(jie)線(xian)完畢后,由1人負(fu)責檢查。
4、測試(shi)結束(shu)后,關閉電源開關。嚴禁帶電拆裝高(gao)壓電纜!
5、儀器(qi)出現不正常(chang)現象,關(guan)閉電源開關(guan),等待(dai)一分鐘(zhong)左右再檢查(cha)。
6、反接線校驗標準介損器(qi)時,將標準介損器(qi)放在(zai)絕緣(yuan)物體(ti)上(shang),離地60-100cm,將高(gao)壓(ya)電纜接頭懸(xuan)空(kong)吊起遠(yuan)離地面,避(bi)免高(gao)壓(ya)線夾對地的(de)分布參(can)數影響數據。
7、高壓電(dian)纜(lan)損壞(huai)時,可以用低壓CX線(xian)懸(xuan)空使(shi)用,本產品高低壓電(dian)纜(lan)接(jie)線(xian)方式(shi)相同,可以互換使(shi)用。。
8、測(ce)量完畢(bi)必須關閉電源(yuan)開關,等待一分鐘(zhong)左右再拆(chai)線。

更多產品選型請來揚州豪泰電力科技有限公司,產品變頻介質損耗測試儀售后無憂,歡迎你前來選購。